Unified Container Inspection & Repair Criteria (UCIRC)
FOR STEEL GENERAL PURPOSE CONTAINERS
(For use at all container interchanges)
Revision 3 21 April 2004
CONTENTS1. Introduction
4. Other items
1.1 GENERAL
1.2 ACCEPTABLE DAMAGE
This is defined as damage that is not to be repaired and includes:
1.3 NON-ACCEPTABLE DAMAGE
This is defined as damage that must be repaired because:
The International Convention for Safe Containers, 1972, as amended (CSC) is violated and container safety is affected;
The Customs Convention is violated;
There is a reduction in the internal height dimension by more than 70mm and/or the internal width / length dimension by more than 50mm;
The container is unsuitable for cargo;
Cracks in welds are present unless otherwise stated; and
Corrosion, not due to paint failure, which causes loss of structural integrity.
1.4 WEAR & TEAR
This is defined as unavoidable change or deterioration of the condition of the container brought about by routine operational use and includes:
General paint deterioration;
Deterioration of door gaskets and fittings;
Deterioration of door fixings arising from deterioration of doors;
Flooring de-laminations resulting from routine cargo loading and unloading cycles.
1.5 MANUFACTURING DEFECTS
![]()
|
COMPONENT |
DAMAGE |
RECOMMENDED REPAIR METHODS |
|
2.1 RAILS, HEADERS & SILLS |
||
|
Top side rail |
Holed, cut, torn, broken, cracked Deformation in excess of 30mm |
Weld or straighten, or straighten and weld, or insert, or section, or renew |
|
Bottom side rail – web
Flange |
Holed, cut, torn, broken, cracked Deformation in excess of 50mm
Cracks or tears which extend into web radius |
Weld or straighten, or straighten and weld, or insert, or section, or renew Weld or straighten and weld |
|
Front & rear headers |
Holed, cut, torn, broken, cracked Deformation in excess of 40mm |
Weld or straighten, or straighten and weld, or insert, or section, or renew |
|
Front & rear sill |
Holes, cut, torn, broken, cracked Deformation exceeding 50mm
|
Weld or straighten, or straighten and weld, or insert, or section, or renew |
|
2.2 POSTS |
||
|
Corner posts
Corner castings |
Holed, cut, torn, broken, cracked
Dents exceeding 20mm
Bend, bow or deformation, if exceeding outer faces of corner castings by +5mm on end face or +10 mm on side face Cracked, deformed, broken Deformation preventing correct twistlock operation |
Weld, or straighten and weld, or insert or renew Straighten, or insert or renew Straighten, or insert or renew
Replace Replace |
|
2.3 FLOOR UNDERSTRUCTURE |
||
|
Fork lift pocket & goose neck tunnel assembly
|
Top plate separation from floor in excess of 10mm or floor screws ineffective Web holed, cut, torn, or cracked in excess of 500mm or extending into a weld connection Lower flange connection to bottom side rail, holed, cut, torn, cracked extending into web radius Web deformation below line of corner castings Top plate pushed up in excess of 50mm, cut, torn or broken Strap broken, cracked, cut, torn, missing |
Straighten or weld, or straighten and weld, or insert, or renew Weld, or straighten and weld, or insert, or renew
Weld, or straighten and weld, or insert, or section or renew
Straighten, or straighten and weld, or insert, or renew
Straighten or weld, or straighten and weld, or insert, or renew
Weld, or straighten and weld, or replace |
|
Cross members |
Web holed, torn, broken, cracked, cut, missing Web deformed in excess of 75mm Web upper flange separated from floor by more than 10mm Bowed up by more than 50mm or below line of corner castings |
Weld, or straighten and weld, or insert, or renew Straighten, or renew Straighten and refix, or renew
Straighten, or renew |
![]()
|
COMPONENT |
DAMAGE |
RECOMMENDED REPAIR METHODS |
|
3.1 FLOOR |
||
|
Floor planks and panels |
Gouge greater than 15mm deep irrespective of length Gouge more than 6mm deep and greater than 150mm wide irrespective of length Delamination or other damage (affecting floor strength) Difference in height between adjacent planks / panels greater than 10mm Holes other than nail holes |
Section or renew
Section or renew
Replace if structural
Refasten
Plug (maximum 25mm diam.) |
|
Floor fastenings |
Protruding Three or more adjacent broken / loose, missing fasteners |
Refasten Refasten or replace |
|
3.2 DOORS |
||
|
Door
|
Holed, cut, torn, broken, cracked component or weld, or deformation affecting security and operation of doors Missing / broken or loose parts which affect door operation or watertightness |
Weld or straighten, or straighten and weld, or patch, or insert, or renew Replace or refix |
|
J Bars |
If interfering with door operation |
Weld or straighten, or straighten and weld, or insert |
|
Data plates |
Loose or missing plates |
Refasten or replace |
|
3.3 PANELS |
||
|
Side / front /roof panels including header plate |
Dents into cube which reduce the internal width by more than 50mm from the inner corrugation including multiple dents, or 70mm from the floor to the roof inner corrugation Holed, torn or cut
Dents exceeding the outer face of corner castings + 40mm |
Straighten, or straighten and weld, patch, insert or renew
Weld, or straighten and weld, patch, or insert
Straighten, or straighten and weld, or patch, or insert |
![]()
|
COMPONENT |
DAMAGE |
RECOMMENDED REPAIR METHODS |
|
Lashing rings |
Broken, cracked or missing or non functional |
Weld, or replace, or straighten |
|
Surfaces |
Glue (Sticky) Odour, infestation, debris, contamination that can be transferred Vents blocked, loose, damaged and not weathertight, missing Graffiti / foreign markings - offensive / possibly offensive |
Clean and/or paint Clean and/or remove
Repair/replace
Repair / remove |
|
ISO decals |
Missing or illegible |
Replace |
|
Rain gutters
|
Damage affecting door operation or exceeding outer face of corner castings +10mm |
Straighten or remove |
|
Hazardous labels |
Remaining on panels |
Remove |